Aegis Stainless SteelFloor ScaleInstallation Manual© 2007 by Fairbanks Scales Inc.All rights reserved51103Revision 1 01/07
c. Cornering the scale: Place a load which is 25% of platform capacity uponthe scale at the corner 1 location. Note the indication. Proceed to eac
Bolt-down plates, ramps, bumper guards, and pit frames are installed as follows:A. Bolt-Down Plates:Bolt down plates are used to keep the scale from s
2. Drill holes using a hammer drill or its equivilent. Clean the hole thoroughly. Insertthe anchor(s) with the nut and washer in place. Tap the an
• Use the drawing in Appendix III for measurements, concrete specifications andamounts. • Make sure the conduit for the scale cable is in place and
A. Load Cell Replacement:1. Remove power to the indicator.2. Remove the platform access cover then the junction box cover and disconnect thefailed l
10. Load Cell Specifications:Specifications Stainless SteelMaterial: Stainless Steel 17-4phResistance: 1000 OhmRated Output: 2 mV/VSafe Overload: 150%
C. Foot Assembly Replacement:1. Lift the platform end and secure using wood blocks for safety.2. Remove the bolt which goes through the load cell an
A. Stainless Steel PlatformsItemPart# Description Models1 See Appendix I Platform Weldment See Appendix I2 63895 Load Cell, 1K LCF HR 4060-2 1K, 2.5K
51103 18 01/07 -- Rev. 1Section of Load Cell2 15/16" RefCorner No. 2Corner No. 31Corner No. 1371081712116151614Bottom ViewCorner No. 4Serial Plat
B. Stainless Steel Lift Deck Platforms:Item Part# Description Models1 See Appendix I Platform Weldment See Appendix I2 23426 Load Cell, 1K 1K, 2.5K2
51103 2 01/07 -- Rev. 1Amendment RecordAegis Stainless Steel Floor Scale51103Manufactured by Fairbanks Scales Inc.821 LocustKansas City, Missouri 641
51103 20 01/07 -- Rev. 113.15.50604-7LOCATE THESELABELSONBASEFRAMEASSYTUBECORNER 2CORNER 1CORNER 4CORNER 3TOP VIEW OF SCALEDETAIL "A"INTERLO
51103 21 01/07 -- Rev. 150604-813.15.BOTTOM VIEW OF SCALEC1C2C3C4HINGE SIDECORNER 1 CORNER 2CORNER 3CORNER 4TOP VIEW OF SCALELOCATETHESELABELSONBASEFR
51103 22 01/07 -- Rev. 1Appendix I: Model MatrixA. Analog Stainless Steel SeriesPlatformProduct # Model Size Capacity Weldment63715 PLF-HR3400-A1 30
A. Stainless Steel Ramps, Bumper Guards and Pit Frames:Bumper PitSizeCap Ramp Guard Frame30" 1K 64059 (30")3' x 3' 1K 63752 (3&ap
51103 24 01/07 -- Rev. 1Appendix III: Standard Pit Frameand Installation Drawing50604-9
51103 25 01/07 -- Rev. 1Appendix IV: Lift Deck Pit Frame Installation Drawing
This page intentionally left blank.51103 26 01/07 -- Rev. 1Fairbanks Scales
51103 3 01/07 -- Rev. 1Table of ContentsSection 1: General InformationA. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A. Introduction:The Aegis Stainless Steel floor scale features a rugged structural rib design and anominal height of three inches -- among the lowest
A. General Service Policy:Prior to installation, it must be verified that the equipment will satisfy the customer'srequirements as supplied, and
The complete installation consists of:1. Verifying the application2. Unpacking3. Floor scale checkout4. Customer and site readiness:a. Is the Loc
D. Unpacking:1. Check that all components are on hand, and agree with the customer's order.2. Remove all components from their packing material
3. Screw two (2) eyebolts into the threaded adapters in the platform top and use aforklift or other lifting means along with chains, cables, or nylon
ii. Intalogix™ Technology Interface (QMB 15291):QMB Intalogix™Terminal Wire Color Function Technology Inst1 Green (-) Excitation 12 Red (+) Excitatio
Komentarze do niniejszej Instrukcji